   power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, circuit breaker ta45 standard- or medical-filter c14 70 c description - panel mount: screw-on mounting from front side - 3 functions: appliance inlet protection class i, circuit breaker type ta45 2- pole, line filter in standard and medical version - quick connect terminals 6.3 x 0.8 mm - alternative: version without line filter 614 5 - we recommend for new applications the new type df1 2 approvals - vde license number: 117118 - ul license number: e72928 characteristics - all single elements are already wired unwired versions available on request - line switch non-illuminated or illuminated thermal overload protection optional with undervoltage- or remote trip release - qualified for use in equipment according iec/en 60950 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor-stock-chec k technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 15 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -10 c to 55 c climatic category 10/055/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 circuit breakers acc. iec/en 60934, ul 1077, csa 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. optional with undervoltage- or remote trip release short circuit capacity icn: at in < 3a/240vac : 10 x in at in 3a/240vac : 300a line switch rocker switch 2-pole non-illuminated or illuminated acc. to iec 61058-1 technical detail s line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 100'000 h acc. to mil-hb-217 f
 power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products dimensions 67.5 mm 3.25 +0.1 0 0.1 43 m3/? 3.6 2 1 ? 6 detail a 50.7 67.5* 13.5 6.3x0.8m m 6.3x0.8m m 36 80 91.5 72 80 r 3 29 0 -0.5 0 +0.2 a * --- version ta45 with undervoltage release technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 3 standard version 2 x 2.5 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 15 standard version 2 x 0.1 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1 15 medical version (m5) 2 x 0.1 47 - 1 diagrams standard version 1) line 2) load medical version 1) line 2) load
 power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 3 a 4 a 6 a 8 a 10 a 15a medical version (m5) 1 a 2 a 3 a 4 a 6 a 8 a 10 a 15a technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 3 standard version 2 x 2.5 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 15 standard version 2 x 0.1 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1 15 medical version (m5) 2 x 0.1 47 - 1
4 power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products
5 power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products packaging unit 20 pcs accessorie s description assorted cover s rear cover 0859.0074 mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder or quick-connect terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to 514 5 connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to 514 5 ... power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to 514 5 ...
6 power entry modules with line filter 5  45 www.schurter.com/pg0 6 emc products 10?000 60 2?000 1?000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 [ x i n ] 10 8 5 4 3 2 1,32 type ta45 rated current i 3... 15 a 1-pole protected 2-pole protected ambient temp. +23 c multiple of rated current t ripping time n 10?000 60 2000 1000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated current [ x i n ] 10 8 5 4 3 2 1,32 t ripping time t ype ta45 rated current i n < 3 a 1-pole protected 2-pole protected ambient temp. +23 c t echnical data (continued) circuit breaker t ripping characteristics i n < 3 a t ripping characteristics i n * 3? ) 15 a effect of ambient temperature 1) the unit is calibrated for an ambient temperature of +23 c. to determine the rated current for a lower or higher ambient tempera- ture, use a correction factor from the table below. * ambient temperature [c] correction factor ?10 0,89 ? 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 order code ta45 (2-pole rocker-switch without accessories) a b t w f 1 5 0 c 0 . 0 0 1 see table 1 order code (order example) wiring 0 w ithout 1 w ith t ype of line filter 1 standard 3 medical rated current of line filter 1 1 (a) 5 6 (a) 2 2 (a) 6 8 (a) 3 3 (a) 7 10 (a) 4 4 (a) 8 15 (a) please note that schurter will establish an internal part number for logistical use in additional to the order code. the format of this internal part number is, for example 5145.0031.001 1) example rated current at +23 c 6,0 a ambient temperature +40 c correction factor 1,08 chosen rated current at + 40 c ambient temperature 6 a x 1,08 = 6,5 a * temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been r eached. t ype 5145. the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.


▲Up To Search▲   

 
Price & Availability of 5145ABDWF060C0511

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X